How do Thermal Studs compare?

A thermal bridge is the part of the wall that allows thermal conduction, the transmission of temperature, from one space to another. Thermal Studs provide a gap in the wall to diminish that thermal transfer. By eliminating the thermal bridge in your wall, you’re allowing the space inside your home to be virtually unaffected by the temperature outside. Thus allowing your HVAC system and other appliances to run less which lowers your BTU consumption and carbon footprint.

Click Chart to Enlarge.

BareNaked Tstud™ Build Your Own Wall Comparison:

    Thermal Break (in) US Imperial Effective R-Value (h*ft(2)F/btu) US Imperial Effective U-Value (h*ft(2)F/btu) Canadian Metric U-Factor

5.5" BareNaked Tstud™

Dense Pack Cellulose, R=3.7/in. 1.5 20.4 0.048 0.27
Dense Pack Fiberglass, R=4.18/in. 1.5 23.0 0.044

0.25

R5 Cont. Rigid Insul & Dense Pack Fiberglass, R=4.18/in. 2.5 28.0 0.036 0.20
5" Closed Cell Spray Foam, R=6.7/in. 1.5 33.5 0.032 0.18
7.25" BareNaked Tstud™ Dense Pack Cellulose, R=3.7/in. 2.25 26.8 0.037 0.21
Dense Pack Fiberglass, R=4.18/in. 2.25 30.3 0.037 0.21
R5 Cont. Rigid Insul & Dense Pack Fiberglass, R=4.18/in. 3.15 35.3 0.030 0.17
5" Closed Cell Spray Foam, R=6.7/in. 2.25 33.5 0.025 0.14

R Value Comparison:

Average R Value of Wall Assembly Framing/Cavity Area
  2x6 2x6+R5 Rigid WarmStud™ R19 Tstud™ R28 Tstud™ RhinoStud™

R21 Batt

20.87 25.87 23.02 23.26    

R23 Batt

    24.64 24.89    
R24 Batt     25.46 25.70   24.27
Flash & Batt     28.51 28.75  

36.55

R30 RockWool         32.36  

U Value Comparison:

Average U Value of Wall Assembly Framing/Cavity Area
  2x6 2x6+R5 Rigid WarmStud™ R19 Tstud™ R28 Tstud™ RhinoStud™

R21 Batt

0.048 0.039 0.043 0.043    

R23 Batt

    0.041 0.040    
R24 Batt     0.039 0.039   0.041
Flash & Batt     0.035 0.035   0.027
R30 RockWool         0.031  
Average RSI Value of Wall Assembly Framing/Cavity Area
  2x6 2x6+R5 Rigid WarmStud™ R19 Tstud™ R28 Tstud™ RhinoStud™

R21 Batt

3.676 4.557 4.054 4.097    

R23 Batt

    4.340 4.383    
R24 Batt     4.483 4.526   4.275
Flash & Batt     5.020 5.063   6.437
R30 RockWool         5.682  

RSI Value Comparison:

Metric U Value Comparison:

Average Metric U Value of Wall Assembly Framing/Cavity Area
  2x6 2x6+R5 Rigid WarmStud™ R19 Tstud™ R28 Tstud™ RhinoStud™

R21 Batt

0.272 0.219 0.247 0.244    

R23 Batt

    0.230 0.228    
R24 Batt     0.223 0.221   0.234
Flash & Batt     0.199 0.198   0.155
R30 RockWool         0.176